Zimmer NCB Periarticular Proximal Femoral Plate (Implant 4262)

About Zimmer NCB Periarticular Proximal Femoral Plate (Implant 4262)

98 yr old frail female patient with periprosthetic fracture above a Zimmer retrograde nail used for lower third shaft fracture within a 12 month period where the options were to revise the nail or to by work around it. Solution: Zimmer NCB periarticular proximal femoral plate with polyaxial screws allowed to by pass the nail and fix the fracture with additional cable around the plate.

Courtesy of Sitsabesan Chokkalingam; Sandwell General Hospital; Birmingham, Westmidlands, UK

Manufacturer:  Zimmer, Inc.

Request Product Information

Disclaimer:

OrthopaedicLIST.com is a list of products and services. Every effort is made to keep this listing as accurate and current as possible. Companies and individuals are encouraged to notify us of errors and omissions. We will respond to such messages of correction in a timely fashion, as our workload permits.

We are non-judgmental of products listed. We are not in the business of evaluating products. We have not evaluated these products. We make no representations as to the quality, effectiveness, suitability or appropriateness of any of the products listed.

As an important component of the service function of OrthopaedicLIST.com, some products continue to be listed that are no longer manufactured and may not be available. We will identify them as such when possible. This allows users to find special instruments and/or components for removal, modification, and/or revision of those products.